Bay Area Test Equipment Inc is one of the leading LED test chamber manufacturers and suppliers,Website:http://www.bacldesign.net, welcome to buy and wholesale cheap and best LED test chambers from us.
BTH Series LED Test Chamber
LED Test Chamber is applicable to environmental adaptability and reliability test in such industrial units as electronics, electrical appliance, battery, especially for LED light test, plastics, food, paper product, vehicle, metal, chemistry, building material, research institution, inspection and quarantine bureau, university etc..
Standard Features:
* SUS304stainlesssteel+arcweldingseamlesswelding
* Fireproof PU+ glass fiber wool insulationmaterial * Multi-layerglassobservationwindow+ Autoheating function* Full-opening +double wing type door+ 10,000 times tested lock* One Φ50mm portholescable port * Coatedfinishing (colorsavailable)or SUS304* Adjustable feet andheavy-duty castors
* High quality craftsmanship, modular design and construction
* Water and electricity separation system
* Fullsystemfunctionswitchesandindicatorlights* Allwiringcolorcodedandlabeled* Systemfaultstatusindicators* Over-temperatureprotectionandalarmswitch* Balancedloadon3phasepower* Powerleakageprotection* Overheatingprotection* Overpressureprotection* Overcurrentprotection
* CFC free refrigerant, in line with international standards
* Adopting international famous compressor ,parts and components
* No condensation and no frost design
* Coppertube/aluminumfincoolingcoilsavailable* Air/Watercooledcondenser * Highefficiencyplatetypeheatexchanger* Dualhigh/lowrefrigerationpressurelimitswitches* Overloadprotection for compressor
* Internal/External humidification
* Pt-100 sensor
* Fastresponsestainlesssteelarmoredhumidifier* ReliableSSRnon-touchcontrolofhumidity* Humidifierfaultprotection,overtemperatureprotection
* 7-inch color LCD touch screen* Operation mode: programmable/ singe point setting* Sensor:PT100 (electronic sensor input is optional )* Communication interface(RS232/RS485)* Network solution, IP address can be set* Built-in detection, fault alarm, reminder function* USB interface
* Alarm and show automatic message reminder
Installation Place Requirements
※ Distance from the wall to both sides more than 800mm, and to the front more than 1500mm.
※Provide independent distribution switchgear, humidification condensate drains, and external power connector device is necessary.
※ Ground level, well-ventilated, no flammable, explosive, corrosive gases and dust;
※ No strong electromagnetic radiation nearby;
※ With floor drain(less than 2 meters from the refrigeration unit);
※ Venus Floor load capacity: not less than 800kg/ m2;
※ Leave adequate space for maintenance
Model Features
1. Model: BTH-1200-40
2. Chamber body
2.1 Workplace Volume
IW 1500 × IH 1000 × ID 800 mm
Inner Volume:about 1.2m3
2.2 External Size
According to the design
3. Temperature
3.1 Temp. Range
-40ºC ~ 150ºC
3.2 Temp. Deviation
±2.0ºC
3.3 Temp. Fluctuation
±0.5ºC
3.4 Tem. Uniformity
±2.0ºC
3.5Heating & Cooling Rate
+20ºC ↓ -40ºC within 60min (no load, ambient temperature is 20ºC)
+20ºC ↑ +100ºC within 45min (no load, ambient temperature is 20ºC)
4. Humidity
4.1 Humidity Range
20%R.H.~98%R.H
3.2Temp. &Humidity Range
3.3 Humidity Deviation
±3.0%RH(>75%RH)
±5.0%RH(≤75%RH)
3.4 Humidity Uniformity
±3.0%RH
3.5 Humidity Fluctuation
±2.0%RH
Note
1.Average temp change rate between highest and lowest temperature without any load and heat dissipation, Refer to IEC60068-3-5 for more details)
2.Performance is measured in the ambient temperature of + 25℃ and sensors are placed at the outlet of air conditioning unit ;
3. Customized sizes and configurations are available.