Health&Medical Flat Pack Conta

Click image to view original image
Price: Negotiable
Min.Order:
Supply
Delivery: Shipment within 3 days since the date of payment
Address: China
Valid until: Never Expire
Updated on: 2016-05-13 10:29
Hits: 741066
Enquiry
Company Detail
 
 
Details
Flat Pack Container House 【SMH-FPS】Flat Pack Container System Our SMH - Flat Pack modular container housing solution arrives in a standard container for loading and unloading off vessels in remote areas with limited port facilities. It comprises modules that can be joined in any configuration to provide apartments,Website:http://www.shyingtang.net, houses or office accommodation as required. It is fast and easy to erect and is designed to meet the prevailing thermal, structural and environmental loads relevant to the region. Advantages of Flat Pack Modular Construction:1. Convenient transportation: It is simple and easy to move around the world as it is packed to the same dimensions as a twenty foot container2. Flexible structure: Each independent module can be assembled in the horizontal and vertical plane to suit multiple configurations3. Fast and efficient installation: Easy to assemble and saves time and money in on-site construction. 4. Cost effective: Savings in transport costs and erection costs is significant. Standard Size Specification Dimension of Flat Pack Container HouseLengthWidthHeightStandard 20HCExternal Size6058mm2438mm2791/2896Internal size5878mm2258mm2445/2550Project 20HCExternal Size6058mm3000mm2791/2896Internal size5878mm2820mm2445/2550Health & Medical Application:1.Health Center,maximum can be mounted 3floors. 2.Country Clinic or hospital ward.Can be used as hospital restaurant or dinning room. Product Details Roof Steel frame:  4mm thick cold rolled & welded steel profiles; welded 4 corners casting with dimensions according to ISO norms, steel purlin. Roof covering/interior: 0.4mm galvanized painting steel both side and polystyrene foaming 60mm in the middle, Insulation: 60mm polystyrene (density 38-40kg/ m3.  To avoid cold bridges.Load capacity: 2,000N/m2K-value: 0.18W/m2kInsulation Thickness:Ceiling Panels: 100mm       9mm white chipboard(V20),  50mm   50mm Steel Sandwich panel100mm   12.7mm Glass Magnesium Board(Option2) Fiber cement floor:  Density: 1.26kg/m3 K= 0.18W/m*k; Waterproof moisture content = 0.13%/m2 Formaldehyde emission = 0.2 mg/ 100g; Deformation, parallel to the bending elasticity = 6055MPa  18mm thick marine grade floor Parallel compressive strength = 88MPa; Formaldehyde emission ≤ 0.4mg/100g; Deformation, parallel to the bending elasticity = 8030MPa; Waterproof, moisture content = 6.0%/m2  Corner Posts :3/4mm thick cold rolled & welded steel profiles; Screwed to the floor base frame and roof frame. or 3mm thick cold rolled & welded steel profiles;  Screwed to the floor and roof frame.Wall panelsExterior Cladding:   0.5mm thick corrugated or flat galvanized coated steel sheet Insulation: 60mm, 70mm, 80mm, 100mm mineral wool/glass wool/PU foamInternal Cladding:Laminated E1–Emission Valued 9mm thick chipboard; Parallel compressive strength = 18.1 MPa; Formaldehyde emission ≤ 0.1mg/100g; Water expansion ratio = 0.2% Low smoke and non- flammable Flammability class A1,non-combustible Smoke density: low smoke emission0.5mm thick galvanized and coated color steel sheet     PAINTING/COATINGAll steel profile will be hot dipped galvanized(45μm)Epoxy zinc primer: min40 micronsPolystyrene coating: min50 micronsTotal coating: D.F.T: Min 90 micronsEXTERIOR DOORSAluminium alloy-door with blind, 870/2040 mm.WINDOWSDimensions: 960mm high*1200 mm wideThe windows are build with PVC materials and fitted with AluminumRolling Shutter. They are equipped with a blinding system and an insect net.ELECTRICAL INSTALLATION:Protection: Protective current switch(40/4E-0.03A), automatic fuses(B-characteristics) of suitable power(10A,16A)Earthing: 1 galvanised strip iron earth electrode(2.5*4mm) with fastening. The buyer/lessee to arrange for the lightning Earth installation on site.Equipment:support two 220V fluorescent fixed in the ceiling support one low noise 220V fan fixed in the wall.Open hole and frame for assembly for air-condition in the future.Others equipment will be fixed by the owner according his requirement such as switch, sockets, networks ware socket, phone socket, and phone will be connected by the owner. Phone wiring providing for easy go through the line. SITING AND ERECTION Any individual container should always be mounted on either wooden or concrete foundation bearers (6 bearers) The same applies to the combining of several CILC Module-Containers in a cluster where units must be positioned over concrete bearers or concrete slabs. Foundation parameters and frost depths would be subject to local demands and soil conditions. Level foundations are necessary for problem-free positioning and friction-free erection of any combination. For assembling please read the appropriate mounting instructions.Packaging & DeliveryPackaging:4 units module-container can be stacked as a ISO container, for easy To transports and moving for shipment. Very overhead rope,for SOC - container lift for handling.PACKING & TRANSPORTATION & INSTALLATION:
Total: 0 [Show All]  Related Reviews
 
More »Our Others Products

[ ProductsSearch ]  [ Add To Favourite ]  [ Tell Friends ]  [ Print Content ]  [ Violation Report ]  [ Close Window ]