Air-cooled Oil Chiller CO-100~

Click image to view original image
Price: Negotiable
Min.Order:
Supply
Delivery: Shipment within 3 days since the date of payment
Address: China
Valid until: Never Expire
Updated on: 2016-05-24 11:11
Hits: 669025
Enquiry
Company Detail
 
 
Details
Shanghai Coxin Technology Co.,Ltd is one of the best air-cooled oil chiller CO-100~350 manufacturers and suppliers in China,Website:http://www.coxintech.com, welcome to buy discount and wholesale low price air-cooled oil chiller CO-100~350 from our factory.   Product Name: Air-cooled Oil Chiller Model No.:  CO-100~350 Product Introduction Oil chiller is a unit to cool down the temperature of hydraulic oil, lubricating oil and cooling oil etc. during producing process. In varies manufacturing fieldsite, the machine tool spindles, bearings and gears get overheat and thermal deformation due to the high speed rotational impact, overheat and thermal deformation cause the displacement of machining parts and degrade the machining accuracy, the oil chiller performs cooling down by circulating oil and prevents oil temperature rise, it is a good assistant to insure the machining accuracy and improve producing quality.   Product Features With cooling/heating capacity from 1.0KW~160KW, special requirement is workable; With branded compressor like Copeland/Hitachi/Sanyo etc., running a high effiency of cooling/heating performance; 3.  New micro-computer controller, Chinesse/English language display, fully automatic PLC based units, easy to operate and set; 4.  "fixed temperature" and "room temperature homology type" two control modes, the user can choose according to actual needs; 5.  Environment friendly refrigerant R-407C/R-134a/R-410A, available 6.  Multiple protection functions, with a variety of fault location display for easy maintenance. Provide passive contact alarm output terminals, coupled with machine control systems to form a closed loop control system, improve the safety of machine control systems; 7.  Both cooling and heating functions, start heating when the oil temperature is below 10 ℃,  stop heating when the oil temperature is up to 15 ℃; 8.  Compact structure, high efficiency and easy to maintain. Product Application Hydraulic machinery, food, pharmaceutical, chemical, laser, plastic etc.. Product Parameters Product Model CO-100 CO-120 CO-150 CO-180 CO-200 CO-250 CO-300 CO-350 Cooling Capacity(W) 10000 12000 15000 18000 20000 25000 30000 35000 Heating Capacity(W) 10000 12000 15000 18000 20000 25000 30000 35000 General Power Supply 3P-50Hz-380V(For special power supply, pls contact us, thanks!) Total Power (W) CO-□ 7570 5300 5960 7140 7880 10530 11760 15230 CO-□P 7600 8320 8980 12500 13230 15890 17120 20580 CO-□PT 7600 8320 8980 12500 13230 15890 17120 20580 CO-□P2T 10370 11290 11940 Total Current (A) CO-□ 10.4 13.2 14.3 19.4 20.4 26.0 27.0 30.2 CO-□P/PT 16.4 19.4 20.4 29.0 30.0 35.8 37.0 39.8 CO-□P2T 22.5 25.4 26.4 Temp. Control Range Fixed Temp. Control Type 15~45℃/Differential Temp. Control Type (Room Temp.+T*℃) control accuracy ±1℃ Compressor Power Supply 3P-50Hz-380V Rated Power (W) 4130 4790 5220 6200 6900 9250 10400 13600 Circulating Flow(L /min) 50 55 55 80 80 100 100 120 Pressure 10~12bar Usage Condition Room Temp.(℃) 5~50 Oil Temp.(℃) 5~55 Medium Hydraulic Oil, Lubrication Oil, Spindle oil Pipe Size(Female Thread) G1’’ G11/4’’ G11/4’’ G11/4’’ G11/4’’ G11/2’’ G11/2’’ G11/2’’ Tank Volume(L) 80 100 120 150 180 200 250 250 Protection compressor overload protection*pump overload protection*high/low pressure protection*anti-freeze protection *motor anti-phase and default phase protection *level, flow measurement*malfunction alarm Note 1. The above cooling capacity is based on the condition of ambient temperature 35℃, oil inlet temperature 35℃ for oil ISO Vg32. 2. There are two types of temperature controlling--fixed Temp. control type and differential Temp. control type. Users may choose suitable one according to the requirement. The lower limit value of both types are 15℃ and T*=0~±9℃. 3. CO-□: without oil pump and tank; CO-□P: with oil pump; CO-□PT with oil pump and tank; CO-□P2T with double oil pump and tank. 4. Heating capacity only for COR type with cooling/heating function, the heating capacity is based on the condition of ambient Temp. 13℃, oil inlet temp. 13℃. 5. For any special requirement, pls feel free to contact us. Our Service Cooling the heat! We are professional at industrial cooling solutions, for industrial chillers(oil chiller, water chiller) we can delivery in 1~2 weeks; each unit of chiller is factory tested before delivery. Normally, the package is inner carton & outter plywooden case for exporting shipment; MOQ of 1pc is acceptable; 3D/CAD drawing and technical support also we can provide. Clients’ satisfaction is our pursuit!
Total: 0 [Show All]  Related Reviews
 
More »Our Others Products

[ ProductsSearch ]  [ Add To Favourite ]  [ Tell Friends ]  [ Print Content ]  [ Violation Report ]  [ Close Window ]