GK800-2T37 AC Motor Inverter

Click image to view original image
Price: Negotiable
Min.Order:
Supply
Delivery: Shipment within 3 days since the date of payment
Address: China
Valid until: Never Expire
Updated on: 2016-05-24 11:45
Hits: 680457
Enquiry
Company Detail
 
 
Details
GK800 Closed-loop Vector Control AC Motor InvertersGK800 Series High Performance AC Motor Inverters,Website:http://www.variable-frequency-inverter.com, adopting most advanced close-loop vector control technology, are able to perform precise control on both asynchronous motors and permanent magnet synchronous motors. GK800 series, one of the real drives leaders, are superb in demanding applications with excellent performance no matter in speed control, torque control, position control, field weakening control, or response time, and so on.Product DescriptionSome advantages of closed-loop vector control AC Motor InvertersBased on the top software and hardware elite, modern and scientific producing workmanship, rigorous quality control systems and management team, GTAKE AC Motor Inverters have many advantages, some of which are listed as below:Apply to asynchronous AC motor and permanent magnet synchronous AC motor;Starting torque:180% at 0.25Hz (SVC pattern), 200% at 0Hz (VC pattern);Speed adjustable range: 1:200 (SVC pattern), 1:1000 (VC pattern);Speed accuracy: +/-0.2% (SVC pattern), +/-0.02% (VC pattern);Over load capability: 150% 1minute, 180% 10s, 200% 0.5s;Abundant frequency command sources;Diverse input and output terminals;Ambient temperature: -10°C~50°C;High precise torque constraint, process PID control, simple PLC, wobble frequency control, contracting brake control, field weakening control, all sides protection, etc.Online and offline autotune of motor parameters can both performed;Extremely short-time acceleration can be performed without any trip, such as 0.1s or 0s from 0Hz to 50Hz;No derating ambient temperature: -10-50 centigrade;Customized products and services are also welcome;Flexible command sources, parameters setting, and all sided equipment protection function automatically;The malfunction ratio is lower than 1% within warranty period, based on the statistics.Technical Features of GK800 series AC Motor Inverters3AC 380V/400V/415V/440V/460V/480V -10%~10%, 50Hz/60Hz -5%~5%ModelPower Rating (kW)Rated Output Current (A)Rated Input current (A)Applicable motor (kW)Brake unitGK800-4T2.2B2.25.59.22.2Built-inGK800-4T3.7B3.7914.93.7GK800-4T5.5B5.51321.55.5GK800-4T7.5B7.51727.97.5GK800-4T11B11243911GK800-4T15B153050.315GK800-4T18.5(B)*18.5396018.5Built-in optionalGK800-4T22(B)*224569.322GK800-4T30(B)*30608630GK800-4T37(B)*377510437GK800-4T45(B)*459112445GK800-4T555511215055Externally mounted when neededGK800-4T757515020175GK800-4T9090176160**90GK800-4T110110210192**110GK800-4T132132253232**132GK800-4T160160310285**160GK800-4T185185350326**185GK800-4T200200380354**200GK800-4T220220430403**220GK800-4T250250470441**250GK800-4T280280520489**280GK800-4T315315590571**315GK800-4T355355650624**355GK800-4T400400725699**400** means GK800-4T110 or above is provided with an external-mounted DC reactor in shipment as default1AC/3AC 208V/220V/230V 50/60Hz -10%~10%, 50Hz/60Hz -5%~5%ModelPower Rating (kW)Rated Output Current (A)Applicable motor (kW)Brake unitGK800-2T2.2B2.2102.2Built-inGK800-2T3.7B3.716.53.7GK800-2T5.5B5.5245.5GK800-2T7.5B7.5307.5GK800-2T11(B)114511Built-in optionalGK800-2T15(B)156015GK800-2T18.5(B)18.57318.5GK800-2T22(B)229622GK800-2T303011230Externally mounted when neededGK800-2T373714437GK800-2T454517645GK800-2T555521055GK800-2T757528875GK800-2T9090310(350)90GK800-2T110110415110Technical Features of GK800 AC Motor InvertersTechnical features of GK800 AC Motor InvertersPower inputRated input voltage3-phase AC208V/220V/230V/240V/380V/400V/415V/440V/460V/480VRated input currentSee Section 2.3 in the User ManualFrequency50Hz/60Hz, tolerance ±5%Allowable range of voltageContinuous voltage fluctuation ±10%, short fluctuation -15%~+10%, i.e. 323V~528V;Voltage out-of-balance rate < 3%, distortion rate as per the requirements of IEC61800-2Power outputApplicable motor (kW)See Section 2.3 in the User ManualRated current (A)See Section 2.3 in the User ManualOutput voltage (V)3-phase: 0~ rated input voltage, error <  ±3%Output frequency (Hz)0.00~ 600.00Hz; unit: 0.01HzOverload capacity150% - 1min; 180% - 10s; 200% - 0.5sControl characteristicsV/f patternsV/f controlSensor-less vector control 1Sensor-less vector control 2Close-loop vector control (including position control)Speed range1:100 (V/f control, sensor-less vector control 1)1:200 (sensor-less vector control 2)1:1000 (close-loop vector control)Speed accuracy±0.5% (V/f control)±0.2% (sensor-less vector control 1 & 2)±0.02% (close-loop vector control)Speed fluctuation±0.3% (sensor-less vector control 1 & 2)±0.1% (close-loop vector control)Torque response<  10ms (sensor-less vector control 1 & 2)<  5ms (close-loop vector control)Torque control accuracy±7.5% (sensor-less vector control 2)±5% (close-loop vector control)Starting torque0.5Hz: 180% (V/f control, sensor-less vector control 1)0.25Hz: 180% (sensor-less vector control 2)0Hz: 200% (close-loop vector control)Positioning accuracy±1 line pulseBasic functionsStart frequency0.00~ 600.00HzAccel/Decel time0.00~60000sCarrier frequency0.7kHz~16kHzFrequency command sourcesDigital setting + keypad ∧/∨Digital setting + terminal UP/DOWNCommunicationAnalog setting (AI1/AI2/AI3)Terminal pulse settingMotor started methodsStarted from starting frequencyDC brake then startedSpeed search startedMotor stopped methodsRamp to stopCoast to stopRamp to stop + DC brakeBasic functionsDynamic brake capacityBrake unit threshold voltage: 650V~750V; service time: 0.0~100.0s; brake units of GK800-4T45 and below are built in or can be built in. See table 2-1DC brake capacityDC brake start frequency: 0.00~600.00HzDC brake current: 0.0~100.0%DC brake time: 0.0~30.00sInput terminals7 digital inputs, one of which can be used for high-speed pulse input. Compatible with active open collectors NPN, PNP and dry contact input.3 analog inputs, one of which supports voltage input only, and the other two are voltage/current programmable.Output terminalsOne high-speed pulse output terminal, 0~50kHz square signal; can output command frequency, output frequency and so forthOne digital output terminalTwo relay output terminalsTwo analog output terminal, voltage/current programmable; can output command frequency, output frequency and so forthEncoder signal terminalCompatible with 5V/12V encoderCompatible with different types of encoder signal input, such as open collector, push-pull and differential, etc.Featured functionsParameter copy, parameter backup, common DC bus, free switchover between two motors’ parameters, flexible parameter displayed & hidden, various master & auxiliary command and switchover, reliable speed search started, a variety of Accel/Decel curves programmable, automatic correction of analog, contracting brake control, 16-step speed control programmable (2 steps support flexible frequency command), wobble frequency control, fixed length control, count function, three faults recorded, over excitation brake, over voltage stall protection programmable, under voltage stall protection programmable, restart upon power loss, skip frequency, frequency binding, four kinds of Accel/Decel time, motor thermal protection, flexible fan control, process PID control, simple PLC, multi-functional key programmable, droop control, asynchronous and synchronous motor parameter identification, field-weakening control, high-precision torque control, V/f separated control, torque control at sensor-less vector control, torque control at close-loop vector control, two encoder signal inputs (support incremental, UVW hybrid and resolver, etc.), flexible deceleration ratio control, zero servo, motor spindle orientation, simple feed forward control, pulse train position controlProtection functionRefer to Chapter 7 - TroubleshootingEnvironmentPlace of operationIndoors, no direct sunlight, free from dust, corrosive gases, flammable gases, oil mist, water vapor, water dro and salt, etc.Altitude0~2000mDe-rate 1% for every 100m when the altitude is above 1000 metersAmbient temperature-10℃~50℃Relative humidity0~95%, no condensationVibrationLess than 5.9m/s2 (0.6g)Storage temperature-40℃~+70℃OthersEfficiency at rated Amps7.5kW and below: ≥93%11~ 45kW: ≥ 95%      55kW and above: ≥98%InstallationWall-mountedIP gradeIP20Cooling methodFan cooledApplications of GTAKE AC Motor Drives  (VFDs)Hoists and CranesTower cranesSufficient start torque, fast response  ;  Two motor profiles programmable;  Contracting brake control;                   Overall protection.Bridge cranesPort cranesConstruction cranesPassenger elevatorsCargo elevatorsWinchesMine hoistsmetal Processing High-speed engraving and milling machinesAdequate output torque at low frequency;  Position control modes programmable;  High precision speed control;  Overall protection;  Abundant interfaces and parameter copy function.Machining centersDeep-hole drilling machinesLathesMilling machinesGrinding machinesWinding and UnwindingPrinting machinesIntelligent process control;  Specific functions;  Molding control;  Overall protection;  Abundant interfaces and parameter copy function.Packing machine sPlastic puffing machinesWire drawing machinesOil Pump Servo DrivesInjection molding machinesPrecise speed,low current;  Precise ,fast responded PID control;  Hardware and structure.Die casing machinesShoemaking machinesBlowing moulding machinesConstruction machineriesWith great advantages of high performance, strong starting torque, and strong overload capacity, multiple control techniques, accurate speed control, high reliability, excellent after-sales service, and competitive price, GTAKE provides highly cost-effective AC drives for distributors and agents around the world!Leave me an inquiry for more details like catalog, pricelist, and distributorship~!
Total: 0 [Show All]  Related Reviews
 
More »Our Others Products

[ ProductsSearch ]  [ Add To Favourite ]  [ Tell Friends ]  [ Print Content ]  [ Violation Report ]  [ Close Window ]