Flat Pack Container House
Advantages of Flat Pack Modular Construction:
1. Convenient transportation: It is simple and easy to move around the world as it is packed to the same dimensions as a twenty foot container
2. Flexible structure: Each independent module can be assembled in the horizontal and vertical plane to suit multiple configurations
3. Fast and efficient installation: Easy to assemble and saves time and money in on-site construction.
4. Cost effective: Savings in transport costs and erection costs is significant.
Standard Size Specification
Dimension of Flat Pack Container House
Length
Width
Height
Standard 20HC
External Size
6058mm
2438mm
2791/2896
Internal size
5878mm
2258mm
2445/2550
Project 20HC
External Size
6058mm
3000mm
2791/2896
Internal size
5878mm
2820mm
2445/2550
Office Application:
1.Office building,maximum can mount 3 floors.
Mini office with meeting room,Website:http://www.shyingtang.net, bathroom and kitchen can be included.
Product Details
Floor Steel frame :
3mm thick cold rolled & welded steel profiles; welded 4 corner castings with dimensions according with ISO norms.
Insulation Thickness: 100mm mineral wool/Fiber-glass / PU
Subfloor board: 0.5mm thick, galvanized steel sheet
Floor Board: 18mm fiber cement board (water resistant v 100) complies with the emission value E1; free of formaldehyde (E1)
Parallel compressive strength = 35.7 MPa;
Formaldehyde emission ≤ 0.4mg/100g;
1.8mm thick synthetic PVC sheet floor covering, welded seams, water soluble adhesive,
Flammability class B1 – hardly combustible;
Smoke density class Q1 – low smoke emission; Welded seams.
Roof Steel frame:
4mm thick cold rolled & welded steel profiles; welded 4 corners casting with dimensions according to ISO norms, steel purlin.
Roof covering/interior: 0.4mm galvanized painting steel both side and polystyrene foaming 60mm in the middle,
Insulation: 60mm polystyrene (density 38-40kg/ m3. To avoid cold bridges.
Load capacity: 2,000N/m2
K-value: 0.18W/m2k
Insulation Thickness:
Ceiling Panels:
100mm 9mm white chipboard(V20),
50mm 50mm Steel Sandwich panel
100mm 12.7mm Glass Magnesium Board(Option2)
Fiber cement floor:
Density: 1.26kg/m3 K= 0.18W/m*k;
Waterproof moisture content = 0.13%/m2
Formaldehyde emission = 0.2 mg/ 100g;
Deformation, parallel to the bending elasticity = 6055MPa
18mm thick marine grade floor Parallel compressive strength = 88MPa;
Formaldehyde emission ≤ 0.4mg/100g;
Deformation, parallel to the bending elasticity = 8030MPa;
Waterproof, moisture content = 6.0%/m2
Corner Posts :
3/4mm thick cold rolled & welded steel profiles;
Screwed to the floor base frame and roof frame. or 3mm thick cold rolled & welded steel profiles;
Screwed to the floor and roof frame.
Wall panels
Exterior Cladding:
0.5mm thick corrugated or flat galvanized coated steel sheet
Insulation: 60mm, 70mm, 80mm, 100mm mineral wool/glass wool/PU foam
Internal Cladding:Laminated E1–Emission Valued 9mm thick chipboard;
Parallel compressive strength = 18.1 MPa;
Formaldehyde emission ≤ 0.1mg/100g;
Water expansion ratio = 0.2%
Low smoke and non- flammable Flammability class A1,non-combustible
Smoke density: low smoke emission
0.5mm thick galvanized and coated color steel sheet
PAINTING/COATING
All steel profile will be hot dipped galvanized(45μm)
Epoxy zinc primer: min40 microns
Polystyrene coating: min50 microns
Total coating: D.F.T: Min 90 microns
EXTERIOR DOORS
Aluminium alloy-door with blind, 870/2040 mm.
WINDOWS
Dimensions: 960mm high*1200 mm wide
The windows are build with PVC materials and fitted with AluminumRolling Shutter. They are equipped with a blinding system and an insect net.
ELECTRICAL INSTALLATION:
Protection: Protective current switch(40/4E-0.03A), automatic fuses(B-characteristics) of suitable power(10A,16A)
Earthing: 1 galvanised strip iron earth electrode(2.5*4mm) with fastening.
The buyer/lessee to arrange for the lightning Earth installation on site.
Equipment:
support two 220V fluorescent fixed in the ceiling support one low noise 220V fan fixed in the wall.
Open hole and frame for assembly for air-condition in the future.
Others equipment will be fixed by the owner according his requirement such as switch, sockets, networks ware socket, phone socket, and phone will be connected by the owner. Phone wiring providing for easy go through the line.
SITING AND ERECTION Any individual container should always be mounted on either wooden or concrete foundation bearers (6 bearers)
The same applies to the combining of several CILC Module-Containers in a cluster where units must be positioned over concrete bearers or concrete slabs. Foundation parameters and frost depths would be subject to local demands and soil conditions. Level foundations are necessary for problem-free positioning and friction-free erection of any combination.
For assembling please read the appropriate mounting instructions.
Packaging & Delivery
Packaging:
4 units module-container can be stacked as a ISO container, for easy
To transports and moving for shipment. Very overhead rope,for SOC - container lift for handling.
PACKING & TRANSPORTATION & INSTALLATION: