PHYSICAL PARAMETERS
1. | Ω - sensing axis, 90°± 0.5° to the reference plane |
2. | Dissipation - 1 W |
3. | Weight - 110 gram (150 gram max) |
4. | Volume - 0.1 litre |
5. | Housing material - aluminum alloy |
6. | Housing protection - powder coating |
7. | Tolerances per ISO 2768-m |
8. | Ingress protection class - IP67 |
Specification
MAIN PARAMETERS ( typical values )
♦ Rate range | 160 deg/s |
Scale Factor (SF) | 8.4 mV/deg/s |
Frequency range | 0... 1 kHz |
Angle random walk | 0.015 deg /√ h |
Bias stability, RMS | 3 deg/h |
SF stability, RMS | 0.1 % |
Readiness time | 0.02 s |
ENVIRONMENT
Temperature operating | -40°C ... +75°C |
Temperature endurance, 2hr | -55°C... +85°C |
Vibration, RMS | 12g, 20Hz...2kHz |
Shocks | 500g, 1 ms |
Acceleration | 5g |
RELIABILITY
MTBF | 60000 hours (20º С, predicted) |
♦♦ Lifetime (predicted) | 15 years |
♦ Precision class - 4 |
♦♦ Estimated for low humidity |
RECOMMENDATIONS AND PRECAUTIONS
1. | Do not deform housing |
2. | Fragile components inside - no shocks, no dro |
3. | Treat as electrostatic sensitive unit |
4. | Is designed to be mounted inside water protected equipment |
5. | Increased humidity shortens essentially lifetime |
6. | Mounting surface must be grounded |
7. | Power must be off during connecting |
8. | Soldering to contacts - by low-temperature solder |