Steel Server Room Anti Static Raised Floor Without Edge Trim CIACA Standard
HT Server Room Access Flooring without Edge Trim / Trimless Raised Floor is made of good quality cold-rolled steel sheet, which is stretched, spot-welded, and coated with epoxy powder after having been phosphoreted. There is foaming cement fully filled. The surface is stuck with covering, without edge trim.
Application
Serve room, data center, control room, laboratory, office building, bank, post telegraph, power control center
Characteristics
- Avoid the disadvantage that edge trim can be fall from panel
- The effect after installation can be flatter and more integrative
- Excellent anti-static performance
- Flame retardant, anti-skid, anti-rust, anti-soil
- Mighty glue, strong wearability, non-bubble, non-degumming
- Class A flame spread and smoke development rating
Our Advantage
Full automatic production lines, supplying raised floor with high and stable performance
Accessories
More designs and colors for your options and projects, pls kindly contact our sales
Technical Paramter
Type | Size | Uniform load | Concentrated load | Rolling load | Impact load | Ultimate load | ||
0.100/2.5mm DEFLECTION | 10PASS | 10KPAAASS | ||||||
FS662 | 600*600*35mm |
14.71 KN/ |
2.94KN | 300KG | 2.45KN | 2.00KN | 100LB/45KG | 8.85KN |
FS800 | 600*600*35mm |
17.78 KN/ |
3.56KN | 363KG | 2.94KN | 2.45KN | 100LB/45KG | 11.25KN |
FS1000 | 600*600*35mm |
22.22 KN/ |
4.45KN | 454kG | 3.56KN | 2.67KN | 150LB/68KG | 14.50KN |
FS1250 | 600*600*35mm |
27.78 KN/ |
5.56KN | 567KG | 4.45KN | 3.56KN | 150LB/68KG | 18.36KN |
FS1500 | 600*600*35mm |
33.34 KN/ |
6.68KN | 680KG | 5.56KN | 4.45KN | 175LB/68KG | 22.17KN |
FS2000 | 600*600*35mm |
44.45 KN/ |
8.89KN | 907KG | 6.67KN | 5.56KN | 175LB/79KG | 29.42KN |
Installation Effect
Main Tools Include
Large push cutter, Infrared ray level instrument, Panel lifter, Screw driver, Wax wires, Level bar, Adz-eye Hammer, Nail, Pencil, Flexible rule, Pedestal adhesive, Tool bag, Broom, etc.
Position Datum Point
Proper datum point can avoid the waste of room, the best choice is to set the intersection point of two walls which are rectangular as datum point. If there is a ramp at door, or space for door to swing, the best datum point should be near door. If designing or partition drawing has marked datum point,it can be considered as final.
Notice
- Datum line: A straight line paralleled to datum line,the longest distance between datum level and datum line is 600mm
- Datum level: It is a wall which owner requires to be installed with whole floor panel.
- Vertical: It is a straight line which is vertical to datum line.The largest distance between the vertical line and adjacent wall is 600mm.
- Note: Pls contact sales for detailed installation method.