Anti Static HPL Calcium Sulphate Raised Floor Galvanized Steel Fireproof
Description:
The Antistatic HPL Calcium Sulphate Raised Floor Wrapped with Galvanized Steel a sandwich construction of galvanized steel sheets to the top and bottom enclosing a high density calcium sulphate core. The edge is then wrapped with a PVC trim to create a fully encapsulated 600mm x 600mm panel. This top surface is stuck with HPL(High Pressure Laminate).
Application
Plant rooms, server rooms, banks, telecommunication centers, smart offices and computer rooms.
Characteristics
- Recoverable and environmental protection
- Good loading capacity and conductivity
- Good sealing and water-proof
- Fire–proof , antisepsis and sound insulation
- Exceptionally high rolling load capacity
- Non-combustible: Fire Resistant Class 0
- Suitable for areas with high humidity and other specialist
- Exceeds PSA MOB PF 2 PS/SPU specification standards
Accessories
More designs and colors for your options and projects, pls kindly contact our sales
Technical Paramter
Loading Capacity In accordance with PSA MOB PF2/SPU | ||||
Testing Item | Heavy Grade | Extra Heavy Grade | Extra Heavy Grade | Description |
Concentrated Load | 4.45KN | 5.56KN | 6.68KN | 24 hours loaded onto the floor system supported by pedestal FFH=80mm, deflection<2.50mm |
Uniform Load | 22.22KN/ | 27.78KN/ | 680KN/ | 24 hours loaded onto the floor system supported by pedestal FFH=80mm, deflection<2.50mm |
Ultimate Load | 14.50KN, didnt collapse |
18.36KN, didnt collapse |
22.17KN, didnt collapse |
5 minutes loaded onto the floor system supported by pedestal FFH=80mm, safety factor>3,without collapse. |
Impact Load | 68kg,didnt collapse |
68kg,didnt collapse |
79kg,didnt collapse |
A steel indentor weighing 4.5kg with a 50mm high to anywhere of the floor system supported by pedestal FFH=800mm, without collapse. |
Installation Effect
Acoustical characteristics
The material structure, design features and high production precision of the access raised floor panels provide excellent acoustic values. The extremely good walk-on properties offer a high degree of comfort and create a perfect working ambience.
Electrostatic characteristics
Electrostatic charges are dissipated, regardless of panel material, by the inherent design features. The ohmic resistance defined in this way permits compliance with earth continuity in accordance with VDE 0100 by the use of suitable floor covering.
Air Ventilation
Either plastic or metal ventilation elements can be fitted into the HT calcium sulphate panel or steel ventilation panels can be installed instead of HT panels to follow the requirements of the under floor air conditioning system.
Ecology
Due to this environment friendly production process and the use of ecological materials the HT panel will be recycable from 90% to 97% at the end of its life - a very important economical aspect nowadays.
Pedestal
Capacity : Vertical Load ( at the center of the head ) 18 KN - 5 minutes without collapse.
Fire resistance
The steadily increasing demand of using incombustible materials to reduce the fire load in the buildings makes the HT Calcium Sulphate Access Floor a most valuable solution offering both functional as well as safety advantages.
Installation
Main Tools Include
Large push cutter, Infrared ray level instrument, Panel lifter, Screw driver, Wax wires, Level bar, Adz-eye Hammer, Nail, Pencil, Flexible rule, Pedestal adhesive, Tool bag, Broom, etc.
Position Datum Point
Proper datum point can avoid the waste of room, the best choice is to set the intersection point of two walls which are rectangular as datum point. If there is a ramp at door, or space for door to swing, the best datum point should be near door. If designing or partition drawing has marked datum point,it can be considered as final.
Notice
- Datum line: A straight line paralleled to datum line,the longest distance between datum level and datum line is 600mm
- Datum level: It is a wall which owner requires to be installed with whole floor panel.
- Vertical: It is a straight line which is vertical to datum line.The largest distance between the vertical line and adjacent wall is 600mm.
- Note: Pls contact sales for detailed installation method.
The Advantage of Raised Floor
- The use of raised floor in the workplace is rapidly gaining popularity since they present a solution that is specifically designed to support information-rich and highly computerised business environments.
- Owners and developers, along with building designers and facility managers, face the challenges of constantly changing space needs, technology-driven operations, high churn rates and the almost impossible task of maintaining flexibility while keeping life-cycle costs down.
- All of these challenges demand a new outlook on planning and constructing buildings and some insight into assuring that all building systems are integrated so they become mutually supporting. The costs of both change and maintenance are exceptionally high in traditionally planned buildings, and in many instances users defer needed changes at the cost of organisational comfort and efficiency.
- In fact, many traditionally designed facilities become obsolete due to wiring and wiring distribution problems created by organisational changes and advances in technology.
- If the building is planned correctly though, with enough thought and creativity, changes can become almost routine and technology can be easily integrated. A well-designed, intelligent building not only has the flexibility and the capacity to accommodate change, it actually promotes change.