OUPUT
DC voltage:12V/24V
Rated current:5A/2.5A
Current range:0~5A/0~2.5A
Rated power:30W/30W
Ripple&noise:80mVp-p/100mVp-p
Setup,rise,hold time:500ms,20ms,20ms/230VAC
INPUT
Voltage range:85~264VAC/120~370VDC
Frequency range:47 ~ 63Hz
Efficiency:84%/84%
AC current:0.8A/115VAC 0.4A/230VAC
Inrush current:Cold start 30A
Leakage current:<0.5mA/240VAC
PROTECTION
Overload: 115 ~ 150% rated output power
Protection type:Constant current limiting, recovers automatically after fault condition is removed
Over voltage:5.8~6.8V/28~32V
Protection type :Shut off
ENVIRONMENT
Working temp,humidity:-20℃ ~ +60℃,20% ~ 90% RH non-condensing
Storage temp, humidity:-20℃ ~ +85℃,10% ~ 95% RH non-condensing
Withstand vibration:10 ~ 500Hz, 2G 10min/1cycle,period for 60min. each axes
SAFETY & EMC
Safety standard:Design refer to UL1012,EN60950-1,EN61347-1,EN-61347-2 approved
Withstand voltage:I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolation resistance:I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMC standard:EN55015,EN55022,EN55024,EN61000-3-2,EN61000-3-3,EN61547 approved
OTHERS
MTBF:500K hrs
Dimension:155*37*25mm (L*W*H)
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.