Ceramic Raised Access Floor System Abrasion Resistant For Bank
Description:
The Stringered High Strength Ceramic Calcium Sulphate Panel Ceramic Raised Floor Bank Usage System forms an extremely stable surface, captured within a stringered understructure. The panel and understructure unite to provide excellent lateral stability and rigidity along with easy underfloor access. This raised floor system is capable of with standing heavy-duty static and dynamic loads experienced within the majority of bank environments.
Application
Banks, telecommunication centers, smart offices.
Characteristics
- Better resistance against abrasion, longer service life
- Excellent anti-static performance
- Higher fire-proof grade as much as 1000
- Good loading capacity and conductivity
- High dimension accuracy and good interchangeability
- Good sealing and water-proof
- Fire–proof , antisepsis and sound insulation
Accessories
More designs and colors for your options and projects, pls kindly contact our sales
Technical Paramter
Loading Capacity In accordance with PSA MOB PF2/SPU | ||||
Testing Item | Heavy Grade | Extra Heavy Grade | Extra Heavy Grade | Description |
Concentrated Load | 4.45KN | 5.56KN | 6.68KN | 24 hours loaded onto the floor system supported by pedestal FFH=80mm, deflection<2.50mm |
Uniform Load | 22.22KN/ | 27.78KN/ | 680KN/ | 24 hours loaded onto the floor system supported by pedestal FFH=80mm, deflection<2.50mm |
Ultimate Load | 14.50KN, didnt collapse |
18.36KN, didnt collapse |
22.17KN, didnt collapse |
5 minutes loaded onto the floor system supported by pedestal FFH=80mm, safety factor>3,without collapse. |
Impact Load | 68kg,didnt collapse |
68kg,didnt collapse |
79kg,didnt collapse |
A steel indentor weighing 4.5kg with a 50mm high to anywhere of the floor system supported by pedestal FFH=800mm, without collapse. |
Fire resistance
The steadily increasing demand of using incombustible materials to reduce the fire load in the buildings makes the HT Calcium Sulphate Access Floor a most valuable solution offering both functional as well as safety advantages.
Structure Performance | |||
Bearing Load Capacity |
In accordance with PSA |
In accordance with PSA MOB, |
In accordance with PSA MOB, |
Fire Resistance | Class0 & Class1(BS476) A1 noncombustuble(EN13501) | ||
Soundproofing | 28-51 dB(With floor covering) 14-70dB(Without floor covering) |
||
longitudinal sound reduction, footfall sound, improvement in footfall,improvement in impact sound | |||
Environmentfriendly | RoHS certificated, and meet the requirement of LEED evaluation for projects. |
Ease of Reconfiguration, and Easy Access
Installing an raised floor system in your workplace allows for increased flexibility and brings with it a number of benefits. When you’re able to house your power, data and telecommunications underneath your raised floor, you will find that your workplace is much more flexible.
You can create functional open plan areas with a flexible environment. All sorts of workplaces can benefit from installing an raised floor, such as:
- Data centres and other computer rooms
- Office buildings
- Banks
- Schools and universities
- Call centres
- Television and film studios
- Museums
- Exhibition areas and showrooms