PostYou are now at: Home » Products » Electrical & Electronics »

Urine Specimen Drug Abuse Test Kit , 5 Panel Drug Test KitGold Colloidal With CE

Click image to view original image
Brand: New Life
Price: 1000.00USD/Piece
Min.Order:
Supply
Delivery: Shipment within 3 days since the date of payment
Address: China
Valid until: Never Expire
Updated on: 2017-09-22 17:26
Hits: 4176
Enquiry
Company Detail
 
 
Details

MultiDrug of Abuse Rapid test,Urine Specimen, High Accuracy, Easily & Quick operation on spot, Gold colloidal method

 

 

 

 

Intended Use

 

 

The Multi-Drug Rapid Test Panel with Adulteration is a rapid chromatographic immunoassay for the detection of drugs and drug metabolites in urine at the following cut-off concentrations in urine:

 

 

Product Cat No Specimen Sensitivity Format Kit Size
Drugs of Abuse (DOA) Tests
AMP YD101S3 Urine 1000 ng/mL 3mm Strip 100T
YD101C4 4mm Cassette 25T
BAR YD201S3 Urine 300 ng/mL 3mm Strip 100T
YD201C4 4mm Cassette 25T
BZO YD301S3 Urine 300 ng/mL 3mm Strip 100T
YD301C4 4mm Cassette 25T
COC YD401S3 Urine 300 ng/mL 3mm Strip 100T
YD401C4 4mm Cassette 25T
MOR(MOP) YD501S3 Urine 300 ng/mL 3mm Strip 100T
YD501C4 4mm Cassette 25T
MET YD601SM Urine 500 ng/mL 3mm Strip 100T
YD601CM 4mm Cassette 25T
MTD YD701S3 Urine 300 ng/mL 3mm Strip 100T
YD701C4 4mm Cassette 25T
MDMA YD801S3 Urine 500 ng/mL 3mm Strip 100T
YD801C4 4mm Cassette 25T
THC YD901S3 Urine 50 ng/mL 3mm Strip 100T
YD901C4 4mm Cassette 25T
BUP YD111S3 Urine 100 ng/mL 3mm Strip 100T
YD111C4 4mm Cassette 25T
PCP YD121S3 Urine 25 ng/mL 3mm Strip 100T
YD121C4 4mm Cassette 25T
K2 YD131S3 Urine 200 ng/mL 3mm Strip 100T
YD131C4 4mm Cassette 25T
OPI YD141S3 Urine 2000 ng/mL 3mm Strip 100T
YD141C4 4mm Cassette 25T
TCA YD151S3 Urine 1000 ng/mL 3mm Strip 100T
YD151C4 4mm Cassette 25T
KET YD161S3 Urine 1000 ng/mL 3mm Strip 100T
YD161C4 4mm Cassette 25T
TML YD171S3 Urine 100 ng/mL 3mm Strip 100T
YD171C4 4mm Cassette 25T
DOA 2-in-1 YD021C5 Urine See Insert 2-in-1 Panel 25T
DOA 3-in-1 YD031C5 Urine See Insert 3-in-1 Panel 25T
DOA 4-in-1 YD041C5 Urine See Insert 4-in-1 Panel 25T
DOA 5-in-1 YD051C5 Urine See Insert 5-in-1 Panel 25T
DOA 6-in-1 YD061C5 Urine See Insert 6-in-1 Panel 25T
DOA 7-in-1 YD071C5 Urine See Insert 7-in-1Panel 25T
DOA 8-in-1 YD081C5 Urine See Insert 8-in-1Panel 25T
DOA 9-in-1 YD091C5 Urine See Insert 9-in-1 Panel 25T
DOA 10-in-1 YD011C5 Urine See Insert 10-in-1 Panel 25T
Alcohol YD151C5 Saliva See Insert Strip 100T

 

 

 

DIRECTIONS FOR USE

 

 

Allow the test, urine specimen, and/or controls to reach room temperature

(15-30ºC) prior to testing.

Bring the pouch to room temperature before opening it. Remove the test panel from the sealed pouch and use it within one hour.

Remove the cap.

With the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the dipstick to at least the level of the wavy lines, but not above the arrow on the test panel.

replac the cap and place the test panel on a non-absorbent flat surface.

Start the timer and wait for the colored line(s) to appear.

The result should be read at 5 minutes. Results may be stable up to 1 hour after test initiation.

 

 

 

INTERPRETATION OF RESULTS

 

(Please refer to the illustration above)

NEGATIVE:* A colored line appears in the Control region (C) and colored lines appears in the Test region (T). This negative result means that the concentrations in the urine sample are below the designated cut-off levels for a particular drug tested.

*NOTE: The shade of the colored lines(s) in the Test region (T) may vary. The result should be considered negative whenever there is even a faint line.

POSITIVE: A colored line appears in the Control region (C) and NO line appears in the Test region (T). The positive result means that the drug concentration in the urine sample is greater than the designated cut-off for a specific drug.

INVALID: No line appears in the Control region (C). Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for Control line failure. Read the directions again and repeat the test with a new test card. If the result is still invalid, contact your manufacturer.

 

 

 

 

QUALITY CONTROL

 

A procedural control is included in the test. A line appearing in the control region

(C) is considered an internal procedural control. It confirms sufficient specimen volume, adequate membrane wicking and correct procedural technique.

Control standards are not supplied with this kit. However, it is recommended that positive and negative controls be tested as good laboratory practice to confirm the test procedure and to verify proper test performance.

Total: 0 [Show All]  Related Reviews
 
More »Our Others Products

[ ProductsSearch ]  [ Add To Favourite ]  [ Tell Friends ]  [ Print Content ]  [ Violation Report ]  [ Close Window ]