The differential pressure indicator signals when pressure dro across element reaches 0.35MPa. As the pressure dro rises to 0.4MPa, the by-pass valve in this filter will open allowing oil flowing directly. When the element being changed or cleaned, the oil of system can counter flow to prevent air and contaminant entering the system.The counter flow has not been filtered and is quarter of this filter flow rate.
Model code
GU • ( ) – H ( )×( )( )( )
1 2 3 4 5 6 7
No.1 With check valve pressure line filter
No.2 BH: Water-glycol; omit if use hydraulic oil
No.3 Pressure class: H: 32MPa
No.4 Flow rate (L/min)
No.5 Filtration accuracy (μm)
No.6 F: flanged connection; omit if threaded connection
No.7 P: with CMS indicator; omit if without indicator
Technical data
Model |
Dia. (mm) |
Flow rate (L/min) |
Filtr (μm) |
Press (Mpa) |
Pressure loss (MPa) |
By-pass setting (MPa) |
Indicator power |
Weight (kg) |
Model of element |
Connection |
|
Initial |
Max. |
||||||||||
GU-H10×*P |
15 |
10 |
3 5 10 20 30 40 |
32 |
0.08 |
0.35 |
0.4 |
24V/48W 220V/50W |
3.9 |
GX-10×* |
Threaded |
GU-H25×*P |
25 |
5.3 |
GX-25×* |
||||||||
GU-H40×*P |
20 |
40 |
8.4 |
GX-40×* |
|||||||
GU-H63×*P |
63 |
0.1 |
10.2 |
GX-63×* |
|||||||
GU-H100×*P |
25 |
100 |
12.4 |
GX-100×* |
|||||||
GU-H160×*P |
32 |
160 |
0.15 |
18.7 |
GX-160×* |
||||||
GU-H250×*P |
40 |
250 |
23.5 |
GX-250×* |
Flanged |
||||||
GU-H400×*P |
50 |
400 |
0.2 |
39.4 |
GX-400×* |
||||||
GU-H630×*P |
53 |
630 |
42.6 |
GX-630×* |
Note:* represents filtration. If the filter fluid is water-glycol, usage pressure is 32MPa, flow rate is 63L/min, filtration accuracy is 10μm the filter is equipped with CMS indicator. The model of the filter is GU•BH-H63×10P, the model of element is GX•BH-H63×10.
Company information
1. Specialty: We are the professional factory to produce the replacement of foreign filter element, we adopt import filter medium from America LYDALL company.
2. Products Applications: The filters be used for metallurgy, petrifaction, spinning, electron & pharmacy, power generation & nuclear power, machining equipment, train internal combustion engine &generator, auto engine &engineering machinery and so on.
3. Test standard:
(1). resistance to rupture of filter element as per ISO 2941
(2). structural integrity of filter element as per ISO 2943
(3). compatibility of filter element as per ISO 2943
(4). filter filtrability as per ISO 4572
(5). filter differential pressure specialty as per ISO 3968
(6). test of flow - differential pressure specility as per ISO 3968
(7). viscosity of test oil