The PZS5 has the dvanced concrete spraying technique, developed from our PZ series dry-mix shotcrete and incorporated the advantages of wet-mix shotcrete. Today, it is a universal concrete spraying machine for the processing of wet or dry mix.
Technical Data:
Output
|
5 M3/h(wet material)
|
8—9 M3/h(dry material)
|
Max.convey dist.
|
35 m
|
200m
|
Max.aggregate size
|
φ15 mm
|
φ15 mm
|
Concrete slump
|
8-15 cm
|
|
Hose inner size
|
φ51/65 mm
|
φ51/65 mm
|
Operating air pressure
|
0.2-0.6 MPa
|
0.2-0.6 MPa
|
Air consumption
|
9-10 /min
|
9-10 /min
|
Discharge height
|
1.17 m
|
1.17 m
|
Rotor Rev.
|
11 r/min
|
11 r/min
|
Main electric motor power
|
7.5 kW
|
7.5 kW
|
Dosing pupmp model
|
BRJ15
|
Do not need
|
Dosing pump rated pressure
|
0.6 MPa
|
|
Dosing pump output
|
17.5-88 L/h
|
|
Overall dimension
|
2050×950×1180 mm
|
2050×950×1180 mm
|
weight
|
1200 kg
|
1200 kg
|
Application:
· Shotcreting for tunnels, hydro-power engineering, mines, underground engineering, civil engineering and slope stabilization, etc.
· Artificial soil seeding for no soil surface, such as rock, sand, and for no fertility soil surface.
· Refractory spraying and repair for industrial kilns or kilns’ inner liner.
Features:
· Going-through rotor and forced vibrating hopper make mixture smoothly falling.
· Hose dosing pump unit provides constant dosing.
· Thin flow conveying method, used for wet-mix and dry-mix shotcrete.
· Reinforced shotcrete with steel or various polyment fibre. For the most specific risks of this machine, safety and compliance with the essential requirements of the Directive has been based on elements of EN ISO 12100-1:2003, EN ISO 12100-2:2003/A1:1995, EN 60204-1:2006 and EN 1050:1997
Drive
Electric (BASIC)
Motor output : 7.5 KW/10hp
Speed range : 1500 rpm
Voltages : 380 V 50 Hz
440 V 50/60 Hz
220 V 50 /60Hz
With air motor (AIR)
Motor output: 8kw/11hp
Speed Range: 400-650 rpm
Pressure: 0.63 Mpa/93psi
Air Consumption: 9.4 m³/min
Theoretical conveying date
|
|||||
Hose Φ (mm)
|
Conveying output1) (m3/h)
|
max. grain (mm)
|
max. conv. dist. (m) Horizontal / Vertical
|
||
BASIC
|
AIR
|
||||
50
|
5
|
3~5
|
15
|
Dry: 200 / 70
Wet: 30/20
|
|
65
|
5
|
3~5
|
20
|
1) With theoretical filling degree of 100%. If motor with 60 Hz =20% higher conveying capacity
Theoretical data for air consumption for conveying
Air consumption (m3/min.) 2)
|
||
Dry spraying
|
Wet spraying
|
|
60 m
|
120 m
|
30 m
|
11
|
12
|
15
|
2) Air consumption data are approximate values and are depending on conveying distance.
CAUTION: For the configuration
AIR (with air motor) it has to be considered:
Total air consumption = Air consumption for conveying + Air consumption for air motor!