Salt spray test chamber is specially designed for the testing of the corrosion resistance of the products after their material surfaces have been treated with electric plating,anodizing,spray coating,anti-rusting oil and other anti-erosion treatment. |
Major specification:
Model |
CZ-60A |
Capacity/ Dimension |
|
Internal capacity |
108 L |
Internal dimension |
600×400×450 W×H×D(mm) |
External dimension |
|
Weight |
60kg |
Maximum watt |
2 KW |
Maximum current |
10A |
Power supply information |
1)AC 220V single phase R,N+ protective grounding;voltage fluctuation range 10%V 2)Frequency fluctuation range:50±0.5HZ; 3)Power supply method:TN-S or TT method 4)Grounding resistance of protection ground wire<4Ω 5)User should equip with relevant capacity air switch or dynamic switch on the installation site,and the switch must control this machine only.When the electrified test sample is put in the test chamber,the power of the test sample should be connected with extra power,don’t use the power of this machine; |
Performance Index |
|
Operating environment condition |
The value is got under condition of environment temp. is +25℃,R.H. is ≤85%,no specimen in the chamber. |
Temp.humi. range |
test chamber temperature: RT~ 50℃ pressure barrel temperature: RT~ 63℃ R.H. ≥85%HR |
Major technical parameter |
temperature resolution:0. 1℃ temperature deviation:±1℃ temperature uniformity:1℃ temperature fluctuation:±0.5℃ spray volume(m1/80cm²/h)1.0~2.0 (get the average value based on at least 16 hours collection) spray pressure:1.00±0.01kgf/cm² PH: neutral 6.5~7.2 acidity 3.0~3.3 control time:1S ~ 9999H set free |
Test standard and condition |
1.GB-T2423.18-2000 sodium chloride alternate salt test method 2.GB-T6461-2002 metal basic covering layer of metal or other inorganic covering layer grade evaluation after be corroded. 3.ASTM.B117-2009 salt spray test 4.JIS H8502 salt spray test method 5.IEC 60068-2-11-1981 salt spray test 6.IEC68-2-52 1996 salt spray test 7.GB T-6461-2002 evaluation standard for salt spray test 8.ISO 9227-2006 salt spray test method 9.GB /T 12967.3-91CASS accelerated acetic acid salt spray test 10.QB-T3828-1999 copper salt accelerated acetic acid salt spray test CASS 11.GB-T5170.8-2008 Electronic Electrician Product Environmental Test salt spray test equipment 12.GB-T5170.11-2008 corrosive gas test equipment test method 13.GJB150.11A-2009 military equipment lab environmental test method salt spray test 14.GB/T2423.17-2008 salt spray test method 15.GB-T10587-2006 salt spray test chamber technical condition 16.CNS 8886-2002 salt corrosion extent evaluation 17.CNS 4159 surface treatment of copper acetate salt spray test method 18.CNS 4158 surface treatment of salt spray test method |
Heating rate |
test lab temperature RT→+50℃≤40 min pressure barrel temperature RT→+63℃≤35 min |
Spray method |
continuous |
The Third Party Calibration |
|
1.Before shipping,if the customer need to calibration by the Third Party(The validity inspect report showed by State Environmental Test Equipment Quality Test Center),the cost and fees will be paid by customer.If the first examination do not qualified,after the supplier improved,the second check fees will paid by the supplier; 2.The customer himself authorizes the State Environmental Test Equipment Quality Test Center to check it. |
Quality Guarantee |
※Our company passed the ISO9001 Quality Certification System in June 2000 and passed the ISO9001 Quality Control System of the 2000 edition of the review. ※Our company implement ISO9001:2000 Standard to make sure the quality. |