 Major Function:

This series of machine adopts the best simulation of sunshine UV spectral fluoresvent UV lamp and combines with control temperature and supply humidity device to imitate the color change, luminance and strength reduction for material; cracking, spalling, pulverization, oxidation and other damaged sunshine (UV section) high temperature, high humidity, condensation and dark period factors, together with UV-light and humid sybergistic effect to the single light fastness or single moisture-proof decreased or lose efficacy for the material. Thus widely used to evaluate the performance of the climate resistance of materials.

Major specification
Model
CZ-UV-1
Sample frame dimension
493×290  (mm)   W×H   total four pcs
Sample dimension

80×290  (mm)   W×H
Each sample frame equips with 6 pcs

External dimension

About 1300×1480×550 (mm) W×H × D  see as below picture
Centre distance among tubes
70mm
Centre distance between sample surface and tube
50±3 mm
Tube length
1220mm
Tube watt
40W
Tube use life
Above 1600h
Tube quantity
four pcs in both front and back, total eight pcs
Weight
80kg

Maximum watt

5 KW

Maximum current

17A

Power supply information

1)AC 220V single phase protective grounding; voltage fluctuation range 10%

2)Frequency fluctuation range:50±0.5 HZ

3)Power supply method: TN-S  or TT method

4)Grounding resistance of protection ground wire<4Ω

5)User should equip with relevant capacity air switch or dynamic switch on the installation site, and the switch must control this machine only. When the electrified test sample is put in the test chamber, the power of the test sample should be connected with extra power, don’t use the power of this machine;

Performance Index

Environment requirement

This two values measured under the condition of no test sample in the chamber

Temp./humid range

irradiation temperature:    50~ 70℃

condensing temperature:    RT~ 60℃

spraying temperature:         room temperature  

relative humidity         ≥85%R.H.

Major technical parameter

temperature resolution: 0. 01℃                  
temperature deviation: ±1℃                    
temperature uniformity: 2℃                
temperature fluctuation: ±0.5℃
irradiance: 0~25W/m2

ultraviolet wavelength: UV-A wavelength coverage:315-400nm

UV-B wavelength coverage:280-315nm

Note: UV tube can choose UV-A / UV-B tube or choose both types mix together use.If no special instruction,when the machine being delivery,we will equip UV-B tube.

Test standard
GB/T16422.3-1997  Part Ⅲ,fluoresvent UV lamp

GB/T14522-2008 artificial weathering aging test method, fluoresvent UV lamp

IEC61215  Part 10.10,part ultraviolet weathering test
Heating rate

irradiation temperature   RT→+70℃≤45 min 

condensing temperature   RT→+60℃≤45 min