Salesjycable[at]hotmail[dot]com
Sheath thickness |
1-10 mm |
Sheath material |
PE |
Wire maximum diameter |
34mm |
type |
BV BLV BVR RVV RVVS RVVP |
Line core material |
Bare copper |
Processing custom |
YES |
Cores |
1-35 |
Properties ,
1. According to the product GB5023, JB8734 national standards
2. Wire submerged 1 hour, the ac fifty hz250v (450/750 v), 2000 v (300/500 v) voltage experimental five minutes without breakdown
Specification :
Type |
De |
Rated voltage |
sum |
nominal cross section |
General use single core hard conductor no shield cable |
450/750 |
1 |
1.5-400 |
|
General use single core soft conductor no shield cable |
450/750 |
1 |
0.12-400 |
|
Internal wiring with conductor temperature of 70 C single core solid core conductor no shield cable |
300/500 |
1 |
0.5-1 |
|
Copper core polyvinyl chloride parallel lines |
450/750 |
2-3 |
0.12-2.5 |
|
Internal wiring with conductor temperature of 90 C single core solid conductor no shield cable |
300/500 |
1 |
0.5-7.5 |
|
PVC insulated ground cord |
450/750 |
2-3 |
0.12-4 |
|
ordinarysheathed flexible cord |
300/500 |
2-32 |
0.12-6 |
|
Aluminum conductor, PVC insulated cable |
450/750 |
1 |
2.5-400 |
|
Copper core PVC soft edge cable |
450/750 |
1 |
0.75-120 |
|
Copper core PVC insulated PVC sheathed flat cable |
300/500 |
2-3 |
0.75-10 |
|
Aluminum conductor, PVC insulated PVC sheathed flat cable |
300/500 |
2-3 |
0.75-10 |
Oil resistant cable: used for numerical control machine tool equipment electrical connection
Waterproof cable: used for outdoor, underground pipelines, CMC channel and humidity larger environment
Rat termite cable: used for
Resistance to low temperature cable: used for outdoor, cold storage equipment working environment, the minimum resistance low temperature - degrees, in low temperature environment cable can still keep soft condition, no crack, convenient operation.
Environmental protection cable: the environmental protection plastics, widely used in environmental protection requirements of strict place.
Flame retardant cable: the flame retardant plastic, in case of fire can effectively prevent fire spread along the wire.
Integrated cable: according to the customer request or sample production lines, the various equipment line, line integrated in a piece of wire inside, plus sheath of protection wiring beautiful and extend cable service life. According to the different use environment can choose oil resistant sheath, waterproof jacket, resistance to low temperature sheath, ring protective sleeve, general PVC sheathed, elastic sheath, flame retardant sheath and so on many kinds of types for wiring operation to provide adequate agility and convenience