Power(W)5W-30W,60W
Output Voltage(KV) 0.3KV-30KV
SUMMARY
The MT serise ie a regulated, versatile,modular HV power supply used in a wide variety of applications including MTss spectrometry and Electron Microcopes.From the OEM to the laboratory,they are an excellent choice when you require a highiy stable output.Output can be controlled using either an external control voltage or external variable resistor.With a diverse range of models up to 6KV/30W,you will find something for nearly every requirement.
SPECIFICATIONS
Input Voltage:
12Vdc for 5W, 24Vdc for 10W,30W and 60W.
Nominal Voltage Range:
11Vdc to 30Vdc for 5W, 23Vdc to 30Vdc for 10W,30W and 60W.
Input Curr ent: (typical)
Disabled: 30mA
No load: 90mA
Full load:
5 watt units: 0.5A
10 watt units: 1.0A
30 watt units: 1.5A
60 watt units: 3.5A
Efficiency:
80-85%, typical
Voltage Re gulation:
Line: <0.01%
Load: <0.01%
Current Re gulation:
Line: <0.01%
Load: <0.01%
Output Voltage:
Continuously adjustable over entire output range. Available
in either positive or negative output polarity. See table for
voltage ranges.
Output Voltage Control: Controlled by either:
1) External potentiometer 100k (set internal pot. to MTx.)
2) Remote differential voltage programming (0 to +5V gives
0 to full output).
Accur acy:
2% on all programming and monitoring,
Temperature Coefficient: (typical)
Optional: 25ppm/°C (T Option)
Environmental:
Temperature Range:
Operating: -40°C to 65°C case temperature
Storage: -55°C to 85°C, non operational
Humidity:
10% to 90%, non-condensing.
Cooling:
Convection cooled, typical. 60 watt units operating at full power
might require additional cooling to maintain case temperature
below 65°C. Methods may include: forced air cooling, use of
heat sink or metal case, etc. It is the user’s responsibility to
maintain the case temperature below 65°C. Damage to the
power supply due to inadequate cooling is considered misuse
and repairs will not be covered under warranty.
Dimensions:
See table
Weight:
See table