70KV 140W X-ray tube Power supply for X-ray gauge

Click image to view original image
Brand: Wisman
型号: XRL70P140
Price: Negotiable
Min.Order: 1 pcs
Supply 10000000 pcs
Delivery: Shipment within 3 days since the date of payment
Address: China
Valid until: Never Expire
Updated on: 2014-09-15 16:42
Hits: 3222607
Enquiry
Company Detail
 
 
Details
 Product Name  XRL

Power(W)75W-200W

Output Voltage(KV)  20KV-160KV

ISO9000:2008 certified precision module .The XRL Series is ideal for OEM applications requiring a competitively priced, precision X-ray tube high voltage module.

Wisman's XRL Series of regulated X-ray power supplies offer output voltages to160kV and incorporate a filament supply which  provides regulated  dc  current  adjustable between 0.3A and 3.5A at 5.5V.High voltage and filament current can be linearly ramped up. The XRL incorporates local and remote programming,monitoring,safety interlock,short-circuit and

overload protection.

TYPICAL  APPLICATIONS:

Plastics Sorting, Crystal Inspection,Plating Measurement ,Diamond Inspection,Mineral

Analysis,X-Ray Fluorescence,X-Ray Diffraction.

OPTIONS:

LR(X)       Low Ripple  0.25%、0.006%、0.003% 、0.001%

USB         USB2.0 Interface

RS232       RS-232 Interface

RS422       RS-422 Interface

DC60        Input  +60Vdc±10%, 5.0A

SPECIFICATIONS:

Input: +48Vdc±10%, 6.25A maximum.

Output: 0 to 160kV at 0 to 2 mA,limited to a maximum of 200watts.

Voltage Control:

Local:Internal multi-turn potentiometer to set voltage from 0 to full output  voltage.

Remote: 0 to +10V dc proportional from 0 to full output  voltage.

Accuracy: ±1%. ZIN: 10Mohm.

Emission Control:

Local: Internal potentiometer to set beam current

between 0  and full output.

Remote: 0 to +10Vdc proportional from 0 to full

output current. Accuracy : ±1%. ZIN: 10Mohm.

DC Filament Supply:

Current:  3.5A, adjustable Voltage:  5.5V

Voltage Regulation:

Load: 0.01% of output voltage no load to full load.

Line: ±0.01% for ±10% change in input voltage.

Current  Regulation:

Load: 0.01% of output current from 0 to rated voltage.

Line: ±0.01% for ±10% change in input voltage.

Ripple: 0.1% p-p of output voltage.

Temperature Range: 0℃to +50℃ operational

Temperature Coefficient:

25ppm/ ℃, voltage or current regulated.

Stability:

≤25ppm/hr after 1/2 hour warm up.

Voltage and Current Monitors:

0 to +10Vdc proportional  from 0 to rated output.

Accuracy:±1%.

Cooling:

Free convection for P≤120W, Fan (30CFM) assisted

for P>120W, except 40KV 。

Dimensions:

0-40KV: L:166mm,W:120mm,D:120mm;

50-70KV: L:230mm,W:100mm,D:140mm;

80-100KV: L:405mm,W:190mm,D:155mm;

110-130KV: L:460mm,W:210mm,D:175mm;

140-160KV: L:515mm,W:230mm,D:195mm.

Total: 0 [Show All]  Related Reviews
 
More »Our Others Products

[ ProductsSearch ]  [ Add To Favourite ]  [ Tell Friends ]  [ Print Content ]  [ Violation Report ]  [ Close Window ]