Product Specifications /Features
Thickness: 1.6mm-4.0mm
Roll Width: 2m
Roll Length: up 20m long
Surface Treatment: UV
Safety Criteria and Performances | NORM | Result |
Fire-proof Classification | EN 13501-1 | Bfl-S1 |
Flammabiltiy | GB 8624-2006 | Bfl-S1 |
Slip Resistance | BGR 181 | R9 |
Dynamic Coefficient of Friction | EN 13893 | DS |
Impact Sound Reduction |
ISO 140-8 GB/T 11982.1-1989 |
12 |
Wear Resistance | EN 649 | T |
Residual Indentation | EN 433 | 0.08mm |
Colour Fastness | ISO 105-B02 | ≥6 |
Dimensional Stability | EN 434 | 0.05% |
Electrical Insulation Ground | VDE 0100 | <200 Kohm |
Thermal Resistance | EN 12667 | <0.17m²K/W |
Static Electrical Resistance | EN 1815 | App.2.0 Kv |
Thermal Ronductivity | EN 12524 | 0.25 W/MK |
INSTALLATION: Installation should be carried out in accordance with local standards. Subfloor to be smooth, hard, clean and dry prior to laying. Where applicable the subfloor must incorporate an effective Damp Proof Membrane. The material must be allowed to acclimatize 24 hours before installation in a room temperature of between 18-24℃.
MAINTENANCE: An emulsion dressing is required. Maintenance should be carried out regularly to retain the appearance and durability of the floor. The floorcovering should be maintained with regular sweeping and damp mopping using a neutral cleanser, more intense cleaning should be carried out using a fine spray cleaning pad under a floor machine, or for larger areas combined machine cleaning.