Static Conductive Self - Leveling Epoxy Resin Floor Paint Finishing Materials
Description:
Epoxy coating is a kind of solvent-free two-component static conductive self-leveling epoxy paint. It can achieve a smooth and beautiful surface which is dust-resistant, anti-corrosion and easy to clean. It can also avoid damage of electronic components and fire due to accumulation of static. Suitable for areas of such industries where anti-static is necessary as electronics, telecommunication, printing, precise machinery, powder, chemical, ordnance, space and engine room.
Advantages of the Finish (Topcoat):
1. Good Self-leveling property, smooth mirror surface;
2. Seamless, dustproof, easy to clean;
3. Solvent-free and environmental friendly;
4. Dense surface, corrosion-resistant;
5. Fast static charge leakage speed, which can avoid damage of electronic components and fire due to accumulation of static;
6. Stable surface resistance, without any influence by high humidity or wear and tear of the surface;
7. Color options (For light colors, black fiber may be obvious)
Application:
It is suitable for areas of such clean room industries where anti-static is necessary as electronics, telecommunication, printing, precise machinery, powder, chemical, ordnance, space and engine room. Especially for workshop and storage areas of electronic instruments and integrated circuit which are highly sensitive to static.
Requirements of the base:
1. Concrete strength≥C25;
2. Flatness: the maximum altitude difference<3mm (measure with 2M running rule)
3. Press polish of the concrete surface with cement mortar is recommended.
4. Water & damp proof treatment is suggested before application of leveling layer of the concrete.
Technical Data:
Model |
CP-7000 A |
CP-7000 B |
|
Color |
Color options |
Light yellow or nearly colorless |
|
Special gravity |
0.95±0.02 |
1.55±0.05 |
|
Mixing ratio |
A : B = 5:1 |
||
Pot life |
60 min. (15) |
30 min. (25) |
15 min. (35) |
Time to walk |
48h (15) |
24h (25) |
12h (35) |
Hard dry |
10 days (15) |
7 days (25) |
4 days (35) |
VOC content |
≤2% (after mixing) |
Notes:
1. The given pot life is based on 5kg ingredients. It will shorten with increased ingredients and temperature.
2. The application environment should be clean, dry and dustless. Control the ventilation properly during application to avoid imperfect coating performance caused by impurities.
3. The surface resistance should be lower than 1.0×104Ω after the primer is dry.
4. Mutiple coats of finish on the static conductive primer are prohibited, or electrical conductivity of the finish will be seriously affected.
5. The paint film will be dull and floating if the relative humidity is above 80% during application and hardening.