01. Nominal power Capacity for Online UPS:
Volts-Amps/Watts(VA/W): 1000VA/700W 2000VA/1400W 3000VA/2100W
02. Online UPS Input
Nominal Voltage: 110/115/120Vac or 220/230/240Vac
Volts-Amps/Watts(VA/W): 1000VA/700W 2000VA/1400W 3000VA/2100W
02. Online UPS Input
Nominal Voltage: 110/115/120Vac or 220/230/240Vac
Voltage Range:60-138VAC or 115-300VAC
Frequency Range:50Hz: 46-54Hz(Default), 60Hz:56-460Hz
Power Factor: ≥0.95 ≥0.97
03. Online UPS Output
Voltage: 110/115/120Vac or 220/230/240Vac
Frequency Synchronized: 46-54Hz or 50Hz± 0.2Hz(Line mode)50Hz± 0.2Hz(Battery mode)
Wave-form: Sine Wave
Distortion: ≤3% (Full linear load) ≤4% (Full linear load)
Overload Capability: 108%-150% for 30sec: ≥150% for 200ms
Crest Ratio 3: 01
04. Online UPS Battery
Type: Sealed Lead-Acid, Maintenance free
Capacity: 12V/7AH*3pcs 12V/7AH*8pcs
Back-up time: (Full /half load) 5mins/14mins 9mins/21mins 5mins/17.5mins
Recharge time: 5hours to 90% of full capacity after full load discharge
05. Online UPS Transfer time: 0ms; 2.5ms typical from inverter to bypass and vice versa
06. Online UPS LED indicators Status Battery level, Battery mode, Line mode, Inverter, Bypass, Overload, fault
07. Online UPS Audible Alarm:
Battery mode: Alarm beeps every four seconds, every second if battery low
Overload: Alarm beeps two for every second
Fault: Alarm beeps continuously
08. Online UPS Acoustic Noise: At 1 meter distance 45dBA 50dBA
09. Online UPS Communications
DB-9 Connector: RS232 Serial interface; Power monitoring and unattended systems shutdown via kavass2002
Intelligent Slot SNMP: Power management from SNMP manager
10.Online UPS Network Surge Protection: RJ45 I/O port available for 10base -T network or Fax/Modem
11. Environment
Operating Temperature: 0-40
Operating Humidity: 20-95% non-condensing
12.Online UPS Applications Servers Data-center, Critical network, Sensitive electronic equipment, Telecom
Frequency Range:50Hz: 46-54Hz(Default), 60Hz:56-460Hz
Power Factor: ≥0.95 ≥0.97
03. Online UPS Output
Voltage: 110/115/120Vac or 220/230/240Vac
Frequency Synchronized: 46-54Hz or 50Hz± 0.2Hz(Line mode)50Hz± 0.2Hz(Battery mode)
Wave-form: Sine Wave
Distortion: ≤3% (Full linear load) ≤4% (Full linear load)
Overload Capability: 108%-150% for 30sec: ≥150% for 200ms
Crest Ratio 3: 01
04. Online UPS Battery
Type: Sealed Lead-Acid, Maintenance free
Capacity: 12V/7AH*3pcs 12V/7AH*8pcs
Back-up time: (Full /half load) 5mins/14mins 9mins/21mins 5mins/17.5mins
Recharge time: 5hours to 90% of full capacity after full load discharge
05. Online UPS Transfer time: 0ms; 2.5ms typical from inverter to bypass and vice versa
06. Online UPS LED indicators Status Battery level, Battery mode, Line mode, Inverter, Bypass, Overload, fault
07. Online UPS Audible Alarm:
Battery mode: Alarm beeps every four seconds, every second if battery low
Overload: Alarm beeps two for every second
Fault: Alarm beeps continuously
08. Online UPS Acoustic Noise: At 1 meter distance 45dBA 50dBA
09. Online UPS Communications
DB-9 Connector: RS232 Serial interface; Power monitoring and unattended systems shutdown via kavass2002
Intelligent Slot SNMP: Power management from SNMP manager
10.Online UPS Network Surge Protection: RJ45 I/O port available for 10base -T network or Fax/Modem
11. Environment
Operating Temperature: 0-40
Operating Humidity: 20-95% non-condensing
12.Online UPS Applications Servers Data-center, Critical network, Sensitive electronic equipment, Telecom