Specifications
1.low frequency double conversion
2.3 phase input & 3 phase output
3.Battery Voltage: 384VDC
4.Payment Terms: T/T, L/C, Westernunio
5.Lead time: 18~20 days
6.Warranty: 2 years
Product Description |
Brief
CHP3000 series ups includes the 10 kVA to 600 kVA (3 phase input & 3 phase output) double conversion On-Line ups with an isolation transformer at Output. The Load is supplied continuously by the inverter with clean, stabilized and regulated sine wave output power. Input & Output filters increase the immunity of load from power disturbances and surges.
CHP3000 series ups used high-speed microprocessor (MCU) and Programmable logic device (CPLD) program which are controlled by software. It brings in the sixth generation low-exhaust and big-power IGBT and static switch as power components. which enter into deduce digital ages of classic legend, bring up with the big capacity, high reliability, stability of function to reside global top-grade level. This series product combines the world’s newest control spare parts and the most advanced software.
CHP3000 series ups entirely break through the technical bottleneck in traditional simulation age,it ingeniously adopt the digital control technology and high-precision SMD technology to assure ultra-high system stability and to fully acclimate various grid environment.
Features:
1.Digital control technique
2.Advanced agenda management software
3.High precision SMD technology
4.The 6th generation IGBT inverter technology
5.Ultra-distinct interface information processing technology
6.Environment friendly and saving technology know-how
Specification
Model | CHP3020k | |
Nominal Capacity (kVA/kW) | 20kVA/16kW | |
Working Mode | Low Frequency Double Conversion True Online | |
Phase | 3 Phase (3L+N+G) | |
Input Power Factor | ≥ 0.9 (6pulse Rectifier+Filter), ≥ 0.96 (12pulse Rectifier+Filter) | |
Rectifier (Input) | Input Nominal Voltage | 380VAC, 400VAC, 415VAC or Optional 200VAC, 208VAC, 220VAC |
Range | ±25% | |
Input Nominal Frequency | 50Hz±10%, 60Hz±10% | |
Input Overtone Current | 6pulse Rectifier<30%, 12pulse Rectifier+Filter<5% | |
Output Ripple Wave | <2% | |
Soft Start | 0~100% 5Sec | |
Charge | Charge Mode | Constant current first then constant voltage, charge with temperature compensation, automatic switch of even charge and float charge, programmable timing battery charge-discharge automatic maintenance |
Float Charging Voltage | 432VDC | |
Equalized Charging Voltage | 464VDC | |
Temperature Compensation Voltage | -03mV/℃(Cell Battery) | |
Charge Current | 0.1C (Automatic adjust according to battery capacity) Example: 100Ah battery, The charge current is setted 10A, or according the charge time customer need |
|
Battery | Type | Maintenance Free Lead-acid Battery, Optional Lithium Battery |
Capacity | 7~999AH settable (capacity vary with power) | |
Battery Number | 384VDC(12v 32pcs or 2v 192pcs), Optional 360VDC (12v 30pcs, or 2v 180pcs) | |
Inverter (Output) | Phase | 3 Phase (3L+N) |
Output Power Factor | 0.8 | |
Nominal Voltage | 380VAC, 400VAC, 415VAC or Optional 200VAC, 208VAC, 220VAC | |
Output Voltage Stability | ±1%(Steady Load), ±3%(Fluctuation Of Load) | |
Frequency Stability | 50Hz,60Hz<±0. 5% ( Asynchronous ) | |
Crest Factor | > 3:1 | |
Output Waveform Distortion Degree | Sine Wave, Linear Load < 3%; Non-Linear Load<5% | |
Dynamic Feature | Transient Voltage<±5%(jump form 0% to 100% ), Instant Recovery Time<10ms | |
Unbalance Load Voltage | < ± 5% | |
Overload Protection | 115% Normal Work, 125% 1min, 150% 1s | |
Invertor Efficiency | 92% (Full Load) | |
Bypass | Phase | 3L+N |
Input Nominal Voltage | 380VAC, 400VAC, 415VAC or Optional 200VAC, 208VAC, 220VAC | |
Output Nominal Voltage | 380VAC, 400VAC, 415VAC or Optional 200VAC, 208VAC, 220VAC | |
Transfer Time | 0ms(Adopted static switch ) | |
Protection Function | Input Protection | Voltage, Frequency Ultralimit, Phase Wrong, Phase Lost |
Output Protection | Overcurrent, Short Circuit, Power Factor Low | |
Battery Protection | Over-charge,Over-discharge | |
Overheat Protection | Environmental Thermal, Inverter Overheat Protection | |
Hardware Fault Protection | Auxiliary power supply abnormal, breaker trip, fuse break, power device over-current or overvoltage | |
Systems Parameters | Economic Running Mode | Economic mode available, overall efficiency reach up to 98% |
Audio Alert Function | Any failure will be alerted | |
Work Environment | Ambient Temperature: 0~40℃, Relative Humidity: 30%~90%, Altitude: <2000M ( power reduce 1% every 100M raised,4000M utmost ) | |
Cooling Method | Forced Ventilation | |
Communication Port | RS232,RS485. Dry Contact Interface,SNMP Card(Network Remote Control) | |
Redundancy Function | Cascade or multiple hot spare | |
Anti-Surge Capacity | 10/700μS, 5kA, 8/20μS, 20kA | |
Protection Level | IP31 | |
Safety Performance | I/O on ground resistance (3000VAC), stray current less than 3.5mA,insulation resistance exceeding 2MΩ(500VDC) | |
Noise(dB) | 48~55 | |
Mechanical Dimension (W×D×H)mm | 600×620×1250 | |
Packing Size (W×D×H)mm | 670×690×1460 | |
Net Weight(Kg) | 265kgs | |
Gross Weight(kg) | 296kgs |