Baykee CHP series low frequency 3 phase20kva solar ups power

Click image to view original image
Brand: Baykee
型号: CHP 3020K 20kva solar ups
规格: CE,EMC,CB,CCC
Price: 1.00USD/piece
Min.Order: 1 piece
Supply
Delivery: Shipment within 14 days since the date of payment
Address: China
Valid until: Never Expire
Updated on: 2015-08-17 16:23
Hits: 2279166
Enquiry
Company Detail
 
 
Details
 Baykee CHP series low frequency 3 phase20kva solar ups power

Specifications
1.low frequency double conversion
2.3 phase input & 3 phase output 
3.Battery Voltage: 384VDC

4.Payment Terms: T/T, L/C, Westernunio

5.Lead time: 18~20 days

6.Warranty: 2 years


Product Description

Brief

CHP3000 series ups includes the 10 kVA to 600 kVA (3 phase input & 3 phase output) double conversion On-Line ups with an isolation transformer at Output. The Load is supplied continuously by the inverter with clean, stabilized and regulated sine wave output power. Input & Output filters increase the immunity of load from power disturbances and surges.

CHP3000 series ups used high-speed microprocessor (MCU) and Programmable logic device (CPLD) program which are controlled by software. It brings in the sixth generation low-exhaust and big-power IGBT and static switch as power components. which enter into deduce digital ages of classic legend, bring up with the big capacity, high reliability, stability of function to reside global top-grade level. This series product combines the world’s newest control spare parts and the most advanced software.

CHP3000 series ups entirely break through the technical bottleneck in traditional simulation age,it ingeniously adopt the digital control technology and high-precision SMD technology to assure ultra-high system stability and to fully acclimate various grid environment.

Features:

1.Digital control technique

2.Advanced agenda management software

3.High precision SMD technology

4.The 6th generation IGBT inverter technology

5.Ultra-distinct interface information processing technology

6.Environment friendly and saving technology know-how

Specification

Model CHP3020k
Nominal Capacity (kVA/kW) 20kVA/16kW
Working Mode Low Frequency Double Conversion True Online
Phase 3 Phase (3L+N+G)
Input Power Factor ≥ 0.9 (6pulse Rectifier+Filter), ≥ 0.96 (12pulse Rectifier+Filter)
Rectifier (Input) Input Nominal Voltage 380VAC, 400VAC, 415VAC or Optional 200VAC, 208VAC, 220VAC
Range ±25%
Input Nominal Frequency 50Hz±10%, 60Hz±10%
Input Overtone Current 6pulse Rectifier<30%, 12pulse Rectifier+Filter<5%
Output Ripple Wave <2%
Soft Start 0~100% 5Sec
Charge Charge Mode Constant current first then constant voltage, charge with temperature compensation, automatic switch of even charge and float charge, programmable timing battery charge-discharge automatic maintenance
Float Charging Voltage 432VDC
Equalized Charging Voltage 464VDC
Temperature Compensation Voltage -03mV/℃(Cell Battery)
Charge Current 0.1C (Automatic adjust according to battery capacity)
Example: 100Ah battery, The charge current is setted 10A, or according the charge time customer need
Battery Type Maintenance Free Lead-acid Battery, Optional Lithium Battery
Capacity 7~999AH settable (capacity vary with power)
Battery Number 384VDC(12v 32pcs or 2v 192pcs), Optional 360VDC (12v 30pcs, or 2v 180pcs)
Inverter (Output) Phase 3 Phase (3L+N)
Output Power Factor 0.8
Nominal Voltage 380VAC, 400VAC, 415VAC or Optional 200VAC, 208VAC, 220VAC
Output Voltage Stability ±1%(Steady Load), ±3%(Fluctuation Of Load)
Frequency Stability 50Hz,60Hz<±0. 5% ( Asynchronous )
Crest Factor > 3:1
Output Waveform Distortion Degree Sine Wave, Linear Load < 3%; Non-Linear Load<5%
Dynamic Feature Transient Voltage<±5%(jump form 0% to 100% ), Instant Recovery Time<10ms
Unbalance Load Voltage < ± 5%
Overload Protection 115% Normal Work, 125% 1min, 150% 1s
Invertor Efficiency 92% (Full Load)
Bypass Phase 3L+N
Input Nominal Voltage 380VAC, 400VAC, 415VAC or Optional 200VAC, 208VAC, 220VAC
Output Nominal Voltage 380VAC, 400VAC, 415VAC or Optional 200VAC, 208VAC, 220VAC
Transfer Time 0ms(Adopted static switch )
Protection Function Input Protection Voltage, Frequency Ultralimit, Phase Wrong, Phase Lost
Output Protection Overcurrent, Short Circuit, Power Factor Low
Battery Protection Over-charge,Over-discharge
Overheat Protection Environmental Thermal, Inverter Overheat Protection
Hardware Fault Protection Auxiliary power supply abnormal, breaker trip, fuse break, power device over-current or overvoltage
Systems Parameters Economic Running Mode Economic mode available, overall efficiency reach up to 98%
Audio Alert Function Any failure will be alerted
Work Environment Ambient Temperature: 0~40℃, Relative Humidity: 30%~90%, Altitude: <2000M ( power reduce 1% every 100M raised,4000M utmost )
Cooling Method Forced Ventilation
Communication Port RS232,RS485. Dry Contact Interface,SNMP Card(Network Remote Control)
Redundancy Function Cascade or multiple hot spare
Anti-Surge Capacity 10/700μS, 5kA, 8/20μS, 20kA
Protection Level IP31
Safety Performance I/O on ground resistance (3000VAC), stray current less than 3.5mA,insulation resistance exceeding 2MΩ(500VDC)
Noise(dB) 48~55
Mechanical Dimension (W×D×H)mm 600×620×1250
Packing Size (W×D×H)mm 670×690×1460
Net Weight(Kg) 265kgs
Gross Weight(kg) 296kgs
Total: 0 [Show All]  Related Reviews
 
More »Our Others Products

[ ProductsSearch ]  [ Add To Favourite ]  [ Tell Friends ]  [ Print Content ]  [ Violation Report ]  [ Close Window ]