Kind of barrier to combine
ExiaⅡBT5
SAF3-5
414S302M-YAi 414S303M-YAi 414S603M-YAi 414S604M-YAi416S302M-YAi
416S303M-YAi 416S603M-YAi 416S604M-YAi
In the case of other explosion-proof barriers and combination *1
Structure of the main valve Pilot spool type
Pilot ceramic slide type Port size
Rc1/4 Rc3/8 Rc1/2 Rc1/4 Rc3/8 Rc1/2
Effective area of valve
25mm2 30mm2 51mm2 60mm2 24mm2 28mm2 51mm2 60mm2
Working pressure 0.2~0.7MPa 0.12~0.7MPa
Ambient temp. -5~50℃ -10~60℃
Explosion-proof standard Intrinsic safety construction
Operating condition
1. Use with specified safety barrier.
For Exia II BT5 explosion-proof valves, use them with the safety barrier SAF3-5 or that meets the
conditions described below (note *1).
2. Parts and connections cannot be changed.
3. Use 1 explosion-proof barrier for each solenoid valve.
note *1
In the case of other barriers and combination
Konan 454, 414, 416 series intrinsic safety solenoid valves have passed equipment qualification tests for intrinsic safety solenoid valve.
The valves can be used in combination with the safety barrier that meets the following conditions. (The valves can be used with insulation barrier that does not need type A ground.)
The barrier used in combination with the valves should be the one that has passed equipment qualification tests for a barrier and that meets the following conditions.
Safety retention voltage
Maximum voltage of a intrinsic safety circuit
Less than 29.4V
Maximum current of a intrinsic safety circuit
Less than 93.8mA
Electric power of a intrinsic safety circuit
Less than 0.689W
Performance classification / Group
Performance classification
ia
Group
ⅡB or ⅡC
Allowable inductance (Lo) and capacitance (Co) for an intrinsic safety circuit and relationship between inductance (Lo) and capacitance (Cw) for external connections to the intrinsic safety circuit
Allowable inductance of a intrinsic safety circuit:Lo≧Li+Lw(mH)
Allowable capacitance of a intrinsic safety circuit:Co≧Ci+Cw(μF)